Sign In | Join Free | My fazendomedia.com |
|
Brand Name : IFM
Model Number : SM6120
Certification : CE
Place of Origin : china
MOQ : 1
Price : USD$470
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 500pc
Delivery Time : 6-8weeks
Packaging Details : carton
Medium temperature [°C] : -20...90
Pressure rating [bar] : 16
Pressure rating [MPa] : 1.6
Current consumption [mA] : < 80
Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 | ||||
---|---|---|---|---|---|
Measuring range |
|
||||
Process connection | G 1/2 DN15 flat seal |
System | gold-plated contacts | ||
---|---|---|---|
Media | Conductive liquids; water; water-based media | ||
Note on media |
|
||
Medium temperature [°C] | -20...90 | ||
Pressure rating [bar] | 16 | ||
Pressure rating [MPa] | 1.6 |
Operating voltage [V] | 18...30 DC; (to SELV/PELV) |
---|---|
Current consumption [mA] | < 80 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 5 |
Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
---|
Inputs | counter reset |
---|
Total number of outputs | 2 |
---|---|
Output signal | switching signal; analog signal; pulse signal; IO-Link; frequency signal; (configurable) |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / closed; (configurable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 100 |
Number of analog outputs | 1 |
Analog current output [mA] | 4...20; (scalable) |
Max. load [Ω] | 500 |
Pulse output | flow rate meter |
Short-circuit protection | yes |
Type of short-circuit protection | yes (non-latching) |
Overload protection | yes |
Measuring range |
|
||||
---|---|---|---|---|---|
Display range |
|
||||
Resolution |
|
||||
Set point SP |
|
||||
Reset point rP |
|
||||
Analog start point ASP |
|
||||
Analog end point AEP |
|
||||
Low flow cut-off LFC |
|
||||
Frequency end point, FEP |
|
||||
Frequency at the end point FRP [Hz] | 1...10000 |
Pulse length [s] | 0.001...2 |
---|---|
Pulse value | 0.001...99990000 I |
Measuring range [°C] | -20...90 |
---|---|
Display range [°C] | -42...112 |
Resolution [°C] | 0.1 |
Set point SP [°C] | -19.6...90 |
Reset point rP [°C] | -20...89.6 |
Analog start point [°C] | -20...68 |
Analog end point [°C] | 2...90 |
In steps of [°C] | 0.1 |
![]() |
IFM Magnetic-inductive Flow Meter SM6120 SMR12XGXFRKG/US-100 Images |