Sign In | Join Free | My fazendomedia.com
China Mengchuan Instrument Co,Ltd. logo
Mengchuan Instrument Co,Ltd.
We have excellent and experienced foreign trade team and other teams to provide you with the best and professional services. Our products are sold all over the world as best-selling products and high
Verified Supplier

4 Years

Home > Differential Pressure Gauge >

high quality Fuji Electric PXF4 Temperature Controller with 50ms sampling speed with best price

Mengchuan Instrument Co,Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

high quality Fuji Electric PXF4 Temperature Controller with 50ms sampling speed with best price

Brand Name : Fuji

Model Number : PXF4

Certification : -

Place of Origin : -

MOQ : 1

Price : USD160/PC

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 100

Delivery Time : 1WEEK

Packaging Details : Original

Warranty : 1 year

model : PXF4

Control output 1 : 250 V AC, 3 A (resistive load)

Relay outpu : 250 V AC, 3 A

name : Fuji

Contact Now

Grobal Sales Section Instrumentation & Sensors Planning Dept. 1, Fuji-machi, Hino-city, Tokyo 191-8502, Japan http://www.fujielectric.com Phone: +81-42-514-8930 Fax: +81-42-583-8275 http://www.fujielectric.com/products/instruments/ Thank you for purchasing the Fuji module type temperature controller. Once you have confirmed that this is the product you ordered, please use it in accordance with the following instructions. For detailed information on operating this equipment, please refer to the separate user's manual. In addition, please keep this instruction manual within easy reach of the actual person using this equipment. Confirming Specifications and Accessories Before using the product, confirm that it matches the type ordered. (For model code, please refer to page 23.) Confirm that all of the following accessories are included. Temperature Controller 1 unit Instruction Manual 1 copy Mounting bracket 1 pc Waterproof packing 1 pc Related Information Refer to the following reference materials for details about the items described in this manual. Document Reference No. Data sheet EDS11-178 Micro Controller (Model: PXF) Operation Manual INP-TN5A2400-E Micro Controller (Model: PXF) Communication Functions Manual (MODBUS) INP-TN5A2227-E The latest manuals can also be downloaded at the following URL: http://www.fujielectric.com/products/instruments/ Please Read First (Safety Warnings) Please read this section thoroughly before using and observe the mentioned safety warnings fully. Safety warnings are categorized as “Warning” or “Caution”. Failure to follow the instructions may result in a safety hazard. Warning mishandling may lead to minor or serious personal injury, fire, and/or property damage. Caution Mishandling may cause injury to the user or property damage. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. 1. Warning 1-1. Limitations in Use This product is a temperature controller which was developed, designed and manufactured on the premise that it would be used for general machinery. In particular, if this product is to be used for applications that require the utmost safety as described below, please take into consideration of the safety of the entire system and the machine by adopting such means as a fail-safe design, a redundancy design as well as the conducting of periodical inspections. • Safety devices for the purpose of protecting the human body • Direct control of transportation equipment • Airplanes • Space equipment • Atomic equipment, etc. Please do not use this product for applications which directly involve human lives. CAUTION The contents of this manual are subject to change without notice. This manual is complied with possible care for the purpose of accuracy, however, Fuji Electric shall not be held liable for any damages, including indirect damage, caused by typographical errors, absence of information or use of information in this manual. 1-2. Installation and Wiring ► This equipment is intended to be used under the following conditions. Ambient temperature -10 °C to 50 °C Ambient humidity 90% RH or below (with no condensation) Overvoltage category II by IEC 61010-1 Pollution degree 2 Recommended fuse 250VAC, 0.1A T(Time-Lag) for 100 to 240V AC Power supply, 400V DC/400V AC, 1A T(Time-Lag) for 24V DC/24V AC Power supply Usage environment Indoor use ► If accessible Safety Extra Low Voltage (SELV) circuits are to be connected to Signal input terminal, SSR Drive output terminal, Current output terminal or Communication (RS485) terminal, ensure to provide a basic insulation between the SELV circuits and these terminals (For example, use transformer which has a basic insulation or higher degree of insulation). The basic insulation requires a clearance at least 1.5 mm and a creepage of at least 3.0 mm. If such insulation is not provided, the UL61010 and EN61010 safety compliance may become invalid. ► For 24V DC/AC power supply model, if the equipment is connected to the Safety Extra Low Voltage (SELV) circuit, a basic insulation must be provided between the SELV circuit and the power input terminals. Otherwise, the power input terminals must be connect to Extra Low Voltage (ELV) circuit so as to prevent the electric shock. ► For CT input, use Current Transfer which has specification as shown below in order to prevent the electric shock and spread of fire. 1) Over Voltage Category II 2) Pollution Degree 2 3) Required level of Insulating BASIC INSULATION, SUPPLYMENTARY INSULATION, or REINFORCED INSULATION 4) Maximum Voltage line to neutral 300Vac rms or 300Vdc About safety standard Please observe the following instructions to meet the requirements of safety standard. Failure to observe these instructions violates safety standards. (This product is not a safety equipment.) ……………………………………………………………………………………………………………………………… ● Install a recommended fuse, which is specified in the instruction manual, between the external main power (mains circuit) and this equipment. ● If accessible Safety Extra Low Voltage (SELV) circuits are to be connected to Signal input terminal, SSR Drive output terminal, Current output terminal or Communication (RS485) terminal, ensure to provide a basic insulation between the SELV circuits and these terminals (For example, use transformer which has a basic insulation or higher degree of insulation). The basic insulation requires a clearance at least 1.5 mm and a creepage of at least 3.0 mm. If such insulation is not provided, the UL61010 and EN61010 safety compliance may become invalid. ● Whole this equipment must be mounted in an enclosure in order to prevent the electric shock and spread of fire. ● Be sure to install an appropriate external protective circuit to prevent excessive temperature rise etc. ● When performing wiring work, be sure to turn the power off and to wear protection gloves or safety glasses, to prevent an electric shock. ● Set proper parameter input signals which correspond to each input to be connected. Be careful not to confuse voltage input with current input, or vice versa. ● Do not use this equipment for the measurement of circuits which falls under measurement categories II, III, or IV. ● Do not use this equipment for measurement of signals to which a voltage over 30 VRMS or over 60 V DC is applied. ● If there is a risk that anyone may come into contact with the terminal while the instrument is being energized, attach the terminal cover (optional) to prevent an electric shock. Before removing a terminal cover, turn off all the power. ……………………………………………………………………………………………………………………………… ► Note that the insulation class for this equipment is as follows. Before installing, please confirm that the insulation class for equipment meets usage requirements. Internal circuit Process value input Remote SV input CT input Control output 1 (SSR drive, current, voltage) Control output 2 (SSR drive, current, voltage) Control output 1 (SSR drive, current, voltage) Control output 2 (SSR drive, current, voltage) Digital input 1 to 3 Communication (RS-485) Power supply (100 to 240V AC) Control output 1 (relay contact) or Motorized valve OPEN output Control output 2 (relay contact) or Motorized valve CLOSE output Alarm output 1 (relay contact) Alarm output 1 to 3 Alarm output 2 (relay contact) (relay contact) Control output 1 (relay contact) or Motorized valve OPEN output Control output 2 (relay contact) or Motorized valve CLOSE output Alarm output 1 (relay contact) Alarm output 1 to 3 Alarm output 2 (relay contact) (relay contact) Basic insulation (1500 V AC) Functional insulation (500 V AC) No insulation (1) (2) (1) (2) Internal circuit Process value input Remote SV input CT input Digital input 1 to 5 Communication (RS-485) Power supply (24V DC/24V AC) (1): When the 9th code is "J" AL 1 and 2: independent common (2): When the 9th code is other than "J" AL 1 to 3: shared common ● A power switch or a circuit breaker should be installed within the power supply facility. ● A power switch or a circuit breaker should be properly installed within easy reach of an operator. ● A power switch or a circuit breaker should be identified as the one for this product. ● Electrical wiring must be made by the qualified personnel only and in accordance with your local and national standards. ● For power supply wiring, use wire equal to 600V vinyl insulated wire or above. ● To prevent damage and failure of the equipment, provide the rated power voltage. ● To prevent shock and equipment failure, do not turn the power ON until all wiring is complete. ● Before turning on power, confirm that clearance space has been secured to prevent shock or fire. ● Do not touch the terminal while the machine is on. Doing so risks shock or equipment errors. ● Never disassemble, convert, modify or repair this equipment. Doing so risks abnormal operation, shock or fire. ● If any failure occurs, please contact the manufacturer and return the product. ● Output relay is the part has a limited life. When output relay contact comes to the end of its life, it might remain on-state, or off-state. For safety, use a protective circuit outside. ● The factory default setting of this equipment is as follows. Change the setting as necessary so as the equipment to meet your application. Please note that the improper settings may result in overheat or unexpected damage


Best high quality Fuji Electric PXF4 Temperature Controller with 50ms sampling speed with best price wholesale

high quality Fuji Electric PXF4 Temperature Controller with 50ms sampling speed with best price Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Mengchuan Instrument Co,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)